Dutch CV boiler guide: low pressure, bleeding radiators, who pays (2026)

Living in the Netherlands › Netherlands life

Dutch CV boiler guide: low pressure, bleeding radiators, who pays (2026)

The central heating boiler, the CV-ketel (say-vay-KAY-tul), is the one piece of Dutch housing equipment that many newcomers meet only when something goes wrong. A radiator stays cold, the display shows a number you do not recognise, or the heating stops on the first frosty morning. Then the questions come quickly: what is a good pressure, can I add water, should I press reset, and do I call the landlord?

This guide covers the CV boiler only. It explains how to read the display, what the pressure numbers mean, how to top up the water (bijvullen), how to bleed radiators (ontluchten), when a reset is fine and when it is not, why carbon monoxide matters, and who pays in a rented home. Everything was checked against manuals and official pages on 18 November 2026.

One caution comes first. Pressure figures differ by manufacturer and model. The examples here come from manuals we could read in full (Remeha and Intergas) and a Bosch page written for Belgium. Look up your own boiler's model number and use its manual.

What this guide is based on

  • Remeha's Calenta 25L user manual, Intergas's Kombi Kompakt HRE operating manual, and a Bosch page for Belgium: pressure ranges, filling, bleeding, errors, servicing
  • The Besluit kleine herstellingen (wetten.overheid.nl) and Rijksoverheid's cost-split page: tenant small repairs versus landlord major work
  • Huurcommissie and Rijksoverheid: what to do when a landlord does not repair, the six-week step
  • Rijksoverheid, co-wijzer.nl and Milieu Centraal: CO safety, certified companies, servicing frequency
  • IamExpat, NL Times, XPAT.NL, DutchNews.nl and ACCESS NL: expat-facing guidance and reporting
What you will learn The short answer
Right pressure Often 1.5 to 2 bar cold; model-specific
Topping up Cold water, slowly, stop at the manual's limit
Bleeding When cold, top valve, then re-check pressure
Errors Fix the cause, reset once, call if it returns
CO alarm and servicing Fit an alarm; use a certified company
Who pays in a rental Small repairs tenant, replacement landlord, servicing by contract

1. The big picture: a closed loop of water

In most Dutch homes with a gas boiler, the boiler heats water and pumps it through pipes to the radiators. That water circulates in a closed loop, separate from the water from your taps. Many boilers also make hot tap water, so one machine does both jobs.

Keep the loop in mind and the rest follows. If water leaves the loop, pressure falls. If air gets into the loop, radiators heat badly or gurgle.

Terms to know

Term Pronunciation and meaning
CV-ketel say-vay-KAY-tul: central heating boiler
waterdruk VAH-ter-drook: water pressure, in bar
bijvullen BAI-ful-en: topping up the water
ontluchten ont-LUKH-ten: bleeding air out
vul-/aftapkraan vul / AHF-tap-krahn: filling and draining tap
onderhoud ON-der-howt: servicing and maintenance
storing STOH-ring: fault or error
huurder / verhuurder HUUR-der / fer-HUUR-der: tenant / landlord

The table shows the words you will meet on manuals, stickers and emails. Landlords and service companies usually understand "CV boiler" plus the model number, so say that when you report a fault.

Not every home has a CV-ketel

Some homes are connected to a district heat network (stadsverwarming) and some have heat pumps. NL Times, reporting on the 2029 hybrid heat pump rule, lists homes on a heat network among the exceptions (see chapter 10). Check your lease or ask your landlord which system you have.

2. Reading the display and the right pressure

The display shows water pressure in bar. Checking it is the most useful routine habit with a CV boiler.

Models differ in when the pressure is shown. Remeha's Calenta 25L shows it in standby. On Intergas's Kombi Kompakt HRE, you switch the boiler off with the on/off button and the temperature display then shows the pressure.

What the manufacturers say

The table compares three sources we could read. The wording differs, but the idea is similar.

Manufacturer and model Target (cold system) Top-up or warning point Source
Remeha Calenta 25L Advised 1.5 to 2.0 bar Top up below 0.8 bar User manual
Intergas Kombi Kompakt HRE 1 to 2 bar Reading flashes below 0.5 bar in operation Operating manual
Bosch (Belgian page) 1.0 to 2.0 bar Newer models warn at 0.8 bar Manufacturer page

The common frame is between 1 and 2 bar, with some models stating a narrower advised range. Many boilers warn or shut down below 0.8 bar, so it is better to top up early than to wait for that.

On a scale of 0 to 3 bar: Remeha Calenta 25L advises 1.5 to 2.0 bar, Intergas Kombi Kompakt HRE 1 to 2 bar, and the Bosch Belgian page 1.0 to 2.0 bar. A dashed line marks 0.8 bar. Remeha 1.5-2.0 Intergas 1-2 Bosch 1.0-2.0 0 1 2 3 bar 0.8 (dashed)
Figure 1: Pressure ranges by manufacturer, in bar, cold system. The dashed line is 0.8 bar (sources: Remeha, Intergas, Bosch Belgium, checked 18 November 2026)

Height changes the pressure you need

Bosch's Belgian page says to add about 0.1 bar for every metre between the boiler and the highest radiator. For radiators in an attic, about 1.5 bar at the boiler keeps at least 1 bar at the top.

In a tall house, or with the boiler on the ground floor and bedrooms on the third, the idea is to keep the pressure in the upper part of the manual's range. Do not go far above 2 bar.

When pressure is too high

Bosch says pressure above 2.0 bar makes the boiler work harder, lowers efficiency and can speed up wear. It names trapped air, overfilling and a filling tap left open as common causes, and suggests letting a little water out at a low radiator valve.

Take out water in small amounts and read the display each time. If you are unsure, ask a service company before releasing water.

3. Topping up the water (bijvullen)

When pressure nears the lower limit, you add water to the loop. In the Netherlands this is a task the rules put on the tenant: the Besluit kleine herstellingen lists "bleeding and topping up the water of the heating installation" (chapter 6).

Procedures differ by model. Remeha's and Intergas's manuals give the steps we can compare.

Before you start

Remeha's Calenta 25L manual asks you to open all radiator valves, turn the room thermostat as low as possible, and wait until the temperature is below 40 degrees and the radiators feel cold before filling. You use a filling hose with two tap connectors, a cloth and a bleed key.

Intergas's manual says to switch the boiler off first and to switch it on again only after filling and bleeding are finished.

Steps (mainly from the Remeha manual)

  1. Read the display. Below 0.8 bar, the manual says to top up
  2. Connect the hose to a cold water tap and let water run through it to push out air
  3. Connect the hose to the filling and draining tap (vul-/aftapkraan)
  4. Open the filling tap, then the water tap, and watch the display
  5. Close the water tap when the pressure reaches 2 bar, then close the filling tap
  6. Bleed the system (chapter 4), read the pressure again and top up if it has dropped

Intergas's order differs slightly: bleed the air out of the hose first, connect it to the tap under the boiler, open the drinking water tap first and then the filling tap, and when finished close the filling tap and then the water tap. It aims for 1 to 2 bar on a cold system.

Figure: top up, bleed, check

Read the pressure on a cold system, add cold water slowly if it is low, bleed the radiators, then read the pressure again and top up if it has dropped. 1. Read when cold 2. Top up cold, slowly 3. Bleed bottom to top 4. Re-check add if lower
Figure 2: Order for topping up and bleeding (sources: Remeha Calenta 25L manual, Intergas manual, checked 18 November 2026)

Do and do not

The table lists the points that most often go wrong when topping up.

Point Do Avoid
Water Cold tap water Warm water
Boiler state Wait until cold Filling a hot system
Amount Add slowly, watch the display Leaving the tap open and walking away
Stop point The manual's limit (Remeha: 2 bar) Going far above 2 bar
Afterwards Bleed, then re-check Stopping after the top-up

The pattern is cool, slow, stop at the limit, check again. Remeha's manual explains why: filling lets air into the loop, and after bleeding the pressure can fall below the required level again.

If you top up often

Remeha's manual says filling and bleeding twice a year should be enough and to contact your installer if you need to add water often. Intergas's manual says that if you have to fill several times a year there may be a leak, and to tell your installer.

Neither manufacturer draws a hard line on the number of top-ups. If you notice you are topping up more often, keep a note of the dates and tell your landlord.

4. Bleeding radiators (ontluchten)

Air trapped in a radiator can leave the top cold, make gurgling noises, or leave a room slow to warm. Intergas's manual lists the steps for a system that is not warm enough: raise the thermostat, open the radiator valves, raise the heating water temperature, then bleed the system and check the pressure.

Milieu Centraal says an older heating system should be bled a few times a year, through the bleed valves on the radiators or the boiler. Newer systems need it less often, but a check before the first cold spell is sensible.

Reading the symptoms

Symptom Likely cause First step
Top cold, bottom warm Air at the top Bleed that radiator
Gurgling Air in the loop Bleed, and check pressure
Whole system lukewarm Low pressure, settings, valves Check pressure, thermostat, valves
Nothing comes out when bleeding Pressure may be too low Read the pressure and top up
One radiator cold Valve or blockage Check the valve; report if it persists

The table shows that symptoms alone cannot tell air from low pressure, so read the pressure before and after bleeding.

Steps (from the Remeha manual)

  1. Open all radiator valves
  2. Set the room thermostat as high as possible and wait for the radiators to warm up
  3. Switch the boiler off and wait about 10 minutes until the radiators feel cold
  4. Bleed from the lowest radiator to the highest
  5. Open the bleed valve a little with the key, hold a cloth against it, and close it when water comes out
  6. Be careful: the water can still be hot
  7. When finished, read the pressure and top up if needed

Intergas's manual adds that the boiler itself has a bleed point at the top left, and that the system can be vented through radiator bleed valves or an air vent in the pipes.

Tips

Air is light and gathers at the top, which is why the valve sits at the top of the radiator. Open it slowly, with a cloth or small cup ready. Stop when water appears: letting water run on only lowers the pressure.

After bleeding

Bosch's Belgian page says a temporary drop in pressure after bleeding is normal. Once you finish, read the pressure on a cold system. If it is below your manual's lower limit (0.8 bar for Remeha, 1 bar for Intergas), go back to chapter 3.

5. Error codes: when a reset is fine and when it is not

When the display shows a code and a red light flashes, the boiler has stopped itself (storing). Codes differ by brand and model, so look yours up in your manual.

The manuals let ordinary users fix only a few things.

What the manuals let you do

Model Type of error What the manual says to do
Remeha Calenta 25L Pressure-related codes (05, 08 to 12) Check pressure: above 0.8 bar, bleed and reset; below 0.8 bar, top up (about 1.5 bar advised) and reset
Remeha Calenta 25L Gas tap code (14) Check the gas tap is open, then reset
Remeha Calenta 25L Other codes Contact the installer; note the code and model details
Intergas Kombi Kompakt HRE Overheating, poor flow Open radiator valves, bleed, check pressure, top up if needed
Intergas Kombi Kompakt HRE No ignition Check the gas tap; reset once the cause is removed

Both manuals say to reset after removing the cause, and to call the installer if the same display returns. Neither recommends resetting over and over.

When a reset is fine

  • You found low pressure and have topped up or bled
  • A closed gas tap has been reopened
  • The manual itself says a reset is the next step for that code

How to reset depends on the model. Remeha's problem table says to hold the reset button for two seconds. When the code clears and the boiler runs normally, you are done.

When not to reset

Situation Reason
You smell gas Possible leak. Do not restart. Open windows, avoid flames and switches, go outside and call for help
A CO alarm has sounded Go outside and call 112. Do not touch the boiler
The same error keeps returning The cause is still there
Water is leaking Do not keep topping up. Tell the landlord
The code is not in your manual The manual says to contact the installer

The table shows that for safety-related or unexplained codes, calling someone comes before resetting.

Note these details before you call

Remeha's manual asks you to note the fault code, gas type, boiler type, production date and serial number before contacting the installer. They are on the type plate on top of the boiler. Photograph the display and the plate; it makes reporting much easier.

6. In a rental: who fixes what

Now the rental question. When the boiler misbehaves, tenants first ask whether it is their cost or the landlord's.

The rule: Besluit kleine herstellingen

Tenant small repairs are set by the Besluit kleine herstellingen (Decree on small repairs), dated 8 April 2003. The current version on wetten.overheid.nl has been in force since 1 August 2003 (checked 18 November 2026). Article 1 says the repairs in its annex are "in any case" small repairs under article 240 of Book 7 of the Civil Code.

For heating, the relevant annex item covers maintaining and replacing parts of technical installations inside the dwelling, where this costs little, is technically simple and needs no specialist knowledge. It names:

  • bleeding and topping up the water of the heating installation
  • restarting the heating installation after a failure
  • replacing filters in mechanical ventilation and keeping the grilles clean

In what we read, periodic boiler servicing and repairs to boiler parts do not appear in that item.

Rijksoverheid's summary

Rijksoverheid says major maintenance (groot onderhoud) is for the landlord's account, with exterior painting and replacing a central heating boiler as examples. Tenants cover day-to-day upkeep such as a toilet seat or a tap washer, and damage they cause.

Where the line falls

Task General split Basis and note
Topping up and bleeding Tenant The annex item. Cold water, slowly
Restarting after a failure (reset) Tenant The annex item. Fix the cause, once
Replacing the boiler Landlord Rijksoverheid (major maintenance)
Repairing inside the boiler Landlord arranges Certified companies only; tenants do not open it
Leaking radiator or broken valve Report to the landlord Listed as defect examples in Huurcommissie's check
Periodic servicing Depends on the contract Not in the annex item. See chapter 7
Damage you caused Tenant Rijksoverheid

The line is roughly a job you can do yourself and that costs little is the tenant's; replacement and internal repair are the landlord's.

Left is the tenant's side: topping up, bleeding, restarting. The middle depends on the contract: servicing and service contract. The right is the landlord's side: replacement and major repair. Tenant top-up, bleeding Contract servicing, plan Landlord replacement
Figure 3: Who pays for what with a rental boiler (sources: Besluit kleine herstellingen, Rijksoverheid, checked 18 November 2026)

Lease clauses

XPAT.NL advises that the lease should say whether the tenant or the landlord is responsible for the yearly cleaning of the heating system and similar items. IamExpat, in a paid partnership article by a law firm, lists bleeding and topping up as tenant small repairs and the boiler's yearly service as the landlord's.

The second is one reading, not a rule for every lease. Because the annex item does not mention servicing, who pays often comes down to the contract and the type of landlord (housing association or private). Check your lease for a servicing clause.

The wider rental rules

For the full list of repair rules and how tenant protections fit together, see our guide to Dutch rental customs and tenant protections. For rent points and using the Huurcommissie, see our rent check guide. This guide covers only the boiler.

7. CO alarms and servicing (onderhoud)

Gas appliances can release carbon monoxide (CO) if combustion or the flue is faulty. It is colourless and odourless. For boiler safety, this is the most important chapter.

The risk, from reporting

NL Times reported that in December 2023, 13 homes on a Hague block were without heat for about three weeks after a CO leak was found following the installation of new boilers; the fire brigade shut the system down on the night of 11 to 12 November.

DutchNews.nl reported in 2014 that poorly installed or maintained central heating boilers caused more CO poisonings than old-fashioned water heaters, citing more than 100 people affected and about 10 deaths a year at that time. That is a decade-old figure, not a current one.

Use a certified company (CO-vrij)

Rijksoverheid says installation, maintenance and repair of a CV boiler, geyser or gas heater must be done by a certified company, and that doing the work yourself is punishable. co-wijzer.nl adds that since 1 April 2023 a certified company is required for any work on a gas appliance.

Certified companies show the CO-vrij logo or appear in the legal register at tlokb.nl. Check before you book. Milieu Centraal also says the company must hold the CO-vrij certificate.

Fit an alarm

Rijksoverheid advises fitting a CO alarm. It does not stop CO being produced; it gives you time to act. co-wijzer.nl gives placement advice.

Where Position Avoid
Room with a boiler or geyser Ceiling, 1 to 3 m horizontally from the appliance, at least 30 cm from walls Near vents and air outlets
Room without an appliance Breathing height Behind curtains or in cupboards
Landing by a bedroom Pillow height Near kitchen cooking appliances
Boiler in the bathroom In the adjoining room Inside the bathroom (moisture damages it)

The table shows that the boiler room ceiling and near where you sleep are the main places. In a rental, ask the landlord about fitting and cost.

When the alarm sounds

co-wijzer.nl gives three steps:

  1. Warn the people in the home
  2. Go outside straight away
  3. Call 112

Symptoms include headache, nausea and dizziness. They resemble flu, so they are easy to miss. Severe poisoning can cause unconsciousness or death. If several people in the home feel ill at the same time, or feel better when away from home, think of CO and get outside. See also our guide to emergency care and 112.

How often to service: official guidance differs

Source Frequency stated
co-wijzer.nl At least once a year, by a CO-vrij company
Rijksoverheid At least once every two years, by a CO-vrij company
Milieu Centraal Older boilers yearly; modern ones every two years in consultation with the installer
Remeha manual Regular inspection; an automatic service message appears at the latest 3 years after installation

We did not find a statutory "once a year" rule in what we read. A sensible reading is yearly for older boilers and one to two years for newer ones, and to ask your landlord or service company.

Remeha's manual asks you to call the installer within two months of a service message appearing. The message may only be reset by a certified installer after the service is done.

Shared flues in apartment blocks

Rijksoverheid says that in apartments and terraced houses the shared flue and air supply must be checked regularly by a certified company, and that the owners' association (vve) or landlord is responsible. The whole building's exhaust matters for safety, not only your own boiler.

8. Who holds the service contract

Who the service contract is with decides who you call.

Situation Who holds the contract How to find out
Housing association or managed home Sometimes the landlord side Lease, move-in pack, helpdesk
Private landlord Landlord or tenant The servicing clause; service sticker on the boiler
You arranged it yourself You Your copy of the contract
No contract, or unknown Unclear Ask the landlord in writing

The "sometimes" in the table is a general tendency, not a fact we confirmed in an official source. Check your own lease and ask your landlord.

Stickers and records

Boilers often carry a sticker with the last service date or a service booklet. Remeha's manual says the service message is reset after the service has been recorded in the service booklet.

When you move in, find out when the last service was, from the sticker or by asking. If you cannot tell, ask in writing to see the service record. It helps later if the boiler fails.

On the day of a service

Clear the space around the boiler. A service company should be able to show its CO-vrij certificate. Mention the boiler's age, how often you top up, and any codes that worry you.

If you are not given a record, note the date and who did the work. Photograph the company's contact details.

9. When it breaks: who to contact, in what order

If the boiler stops, hot water fails or water leaks, deciding the order of contact in advance saves panic.

First make things safe. Then write to the landlord. Then contact the service company if you have a service contract. If the landlord does not act after six weeks, move to the advice route for your type of home. 1. Safety CO, gas smell 2. Landlord in writing 3. Servicer if you have a contract 4. Week 6 escalate
Figure 4: Order of contact when the boiler breaks (sources: Rijksoverheid, Huurcommissie, checked 18 November 2026)

Who to contact for what

Situation First step Contact
Gas smell or CO alarm Open windows, go outside 112
Heating or hot water stopped Check pressure, gas tap, reset once Landlord, service-contract company
Water leaking Stop topping up, take photos Landlord (leaks appear in Huurcommissie's check too)
Same error returns Note the code Landlord, installer
No reply from the landlord Write again Escalate after six weeks

The pattern is 112 for safety, and a written report to the landlord for everything else.

How to write to the landlord

Huurcommissie advises reporting defects to the landlord in a clear letter or email. If you use an email as evidence, the landlord's address and the send date must be clearly visible. A model letter is available.

Useful content: the symptom and when it began, the boiler model and error code, what you have already tried (checking pressure, topping up, reset), photos, and the date you want a reply by. Both Huurcommissie and Rijksoverheid advise giving the landlord six weeks.

If the landlord does not repair

Rijksoverheid sets out these steps:

  1. Write to the landlord listing the defects and ask for repair within six weeks
  2. If nothing happens, ask the municipality (Bouw- en Woningtoezicht). If it agrees the home breaches building rules, it sends the landlord a formal notice and can have work done at the landlord's expense
  3. Ask the kantonrechter (a judge) for a repair order. To ask to change the lease, do it within six months of your defects letter
  4. In social rental, after six weeks the Huurcommissie can temporarily lower the rent (it cannot force repairs)
  5. Free legal advice is available from the Juridisch Loket

Huurcommissie's page says the procedure covers tenants in social and middle-sector rentals, through MijnHuurcommissie with DigiD ("Huurverlaging bij onderhoudsgebreken"). For free-sector rentals, Rijksoverheid points to the court.

Huurcommissie only handles serious defects. Its heating page in the Gebrekencheck lists water leaking from heating taps, radiators or pipes, and a radiator valve that no longer works so the room cannot be heated. A boiler error on its own is not listed there.

The route by type of home

Type of home Main route if the landlord does not repair
Social rental Huurcommissie after six weeks (temporary rent reduction)
Middle-sector rental Huurcommissie (serious defects)
Free sector Kantonrechter; advice from the Juridisch Loket
All The municipality's Bouw- en Woningtoezicht

Your type depends on the rent and contract. If you are unsure which applies, our rent check guide shows how to check.

10. A ten-minute check before winter

Before the first cold spell, go through these in order.

Pre-winter checklist

Step Check Aim
1 Boiler pressure on a cold system In your manual's range (around 1 to 2 bar)
2 Radiator valves All open
3 Bleeding Close when water appears
4 Pressure after bleeding Top up if below the lower limit
5 Space around the boiler Nothing stored there
6 CO alarm Test as the alarm's manual says
7 Last service date Sticker or record
8 Contacts for faults Landlord and service company noted

The eight steps need almost no tools and cost almost nothing. None of them is servicing or repair.

Temperature settings

Milieu Centraal suggests setting the heating water to 50 or 60 degrees and seeing whether the home stays warm enough. For hot tap water it says not to go below 60 degrees, because of the risk of Legionella.

For heating costs and indoor temperature targets, see our guide to Dutch energy bills for 2027. For damp, ventilation and winter in general, see our winter daylight and preparation guide. This guide stays with the equipment.

Recent development: hybrid heat pumps

NL Times reported that on 7 October 2026 the housing minister said that from 2029, homeowners replacing a central heating boiler must install a smart hybrid heat pump. Apartments, listed buildings, homes on a heat network and homes built after 2018 are among the exceptions.

From that report we could not tell whether keeping an existing boiler, or a landlord replacing one in a rental, is affected. Ask your landlord about any replacement plans.

11. Answers by situation

These are situations, not named people. Each shows what to do first.

Situation First step Contact
Just moved in, pressure unknown Read the display and the manual's range Landlord (ask for the model)
Radiators cold Thermostat, valves, bleeding, pressure Landlord if it persists
Pressure drifting to 0.8 bar Top up when cold Landlord if frequent
An error appears Note the code, check the cause Landlord or servicer if it returns
Alarm sounds Go outside 112
Whole block has no heat Ask the managing agent or vve Landlord, agent
Service letter arrives Check the contract for who pays Landlord

Whatever the situation, pressure, valves and settings come first, and contact follows if that does not fix it.

12. What not to do

Do not Why
Open the casing and touch parts Only certified companies may work on it; DIY is punishable
Fill a hot system The manual says wait until it is cold
Reset repeatedly The cause is still there; call a servicer
Leave the filling tap open and walk away The pressure can overshoot
Operate the boiler in a gas smell Flames or switches can ignite gas; go outside
Leave the CO alarm without a battery It cannot warn you
Report a fault by phone only There is no record; write it down
Throw away service records They help show who is responsible

13. Checklist

  • I have noted the boiler's model number and saved the manual
  • The cold pressure is within my manual's range
  • I have bled the radiators before this winter
  • I know the topping-up steps: cold, slowly, stop at the limit
  • A CO alarm is fitted and tested
  • I know when the last service was
  • I have checked my lease for who pays for servicing
  • I have the landlord's and servicer's contact details
  • I remember: 112 for emergencies, written notice to the landlord otherwise

14. Summary

  • Pressure is typically about 1 to 2 bar on a cold system, and varies by model (Remeha advises 1.5 to 2.0 bar). Your manual's figure wins.
  • Top up when cold, with cold water, slowly, and stop at the manual's limit (Remeha: 2 bar).
  • Bleed when the radiators are cold, bottom to top, then re-check the pressure and top up if it has dropped.
  • Reset an error once after fixing the cause. If it returns, call. If you smell gas or a CO alarm sounds, go outside and call 112.
  • Only CO-vrij certified companies may work on the boiler. Servicing guidance ranges from yearly to every two years.
  • In a rental, bleeding and topping up are the tenant's, replacement is the landlord's, and routine servicing depends on the contract.

Your answer can change with your own contract and rent type. When unsure, contact the Juridisch Loket, the Huurcommissie (088 1 600 300) or your municipality.

Sources we used

Manufacturer manuals

Law, government and public bodies

Expat media and reporting

Main information was checked on 18 November 2026. Pressure figures, servicing frequency and rules vary by model and contract. Before doing any work, check your own boiler's manual and the official pages for the latest details.

FAQ

What water pressure should a Dutch CV boiler have?
Most manuals give a range around 1 to 2 bar on a cold system, but it varies by model. Remeha's Calenta 25L advises 1.5 to 2.0 bar and says to top up below 0.8 bar; Intergas's Kombi Kompakt HRE says 1 to 2 bar (checked 18 November 2026). Use your own manual.
My CV ketel shows low pressure. Can I top up the water myself?
In a rental, yes: the Besluit kleine herstellingen lists bleeding and topping up the heating water as a small repair for the tenant. Wait until the system is cold, add cold water slowly, stop at the limit in your manual, then bleed the radiators and check again. Frequent top-ups suggest a leak, so tell the landlord.
How do I bleed a radiator in the Netherlands?
Turn the heating off and let the radiators cool, then open the small valve at the top with a radiator key until air stops hissing and water appears, and close it. Remeha's manual works from the lowest radiator upwards. Bleeding lowers the pressure, so read the boiler display afterwards and top up if needed.
Can I reset my boiler when it shows an error?
Reset once, after you have dealt with the cause: top up low pressure, or open a closed gas tap. If the same error returns, stop resetting and contact the landlord or your service company. Never reset if you smell gas or a CO alarm has sounded.
My rental boiler broke. Who pays to fix it in the Netherlands?
Major work such as replacing a boiler is the landlord's cost (Rijksoverheid). Tenants cover small repairs like bleeding and topping up, and damage they cause. Who pays for routine servicing depends on your contract. Report faults to the landlord in writing and keep a copy.
How often must a Dutch boiler be serviced?
Official guidance differs. co-wijzer.nl says at least once a year, Rijksoverheid says at least once every two years, and Milieu Centraal says yearly for older boilers and every two years for newer ones (checked 18 November 2026). Use a CO-vrij certified company.